QuickTOCpharma TOC Analyser

  • Measurement range: 0 - 2,000 µg/l
  • Response time: < 3 min
  • TOC monitoring
  • Easiest calibration and validation (QuickCalibration)
  • Highest combustion temperature (1,200°C) on the market
  • Catalyst-free technique
  • Closed system to prevent contaminations
  • Software according to 21 CFR Chapter 11
  • Single and dual-stream operation
  • No memory effects
  • Low operational cost
  • According to USP Chapter 643 and EP 2.2.44
   QuickTOCpharma

Applications

Options

Housings

  • Ultra pure water
  • Highly purified water (HPW)
  • Water for injection (WFI)
  • Detailed application overview
  • FlowSampler
  • Multi-stream measurement
  • Combination with TNb detection
  • IP54 (Standard)
  • NEMA 4X
  • ATEX Zone I
  • ATEX Zone II

Online-TOC-Measurement for ultra-pure waters in the pharmaceutical industry. Optimal process control.

LAR's QuickTOCpharma is the ultimate online TOC analyser for the determination of total organic carbon (TOC) for pharmaceutical waters.

Warm, warmer, hot. Tracking organic load at 1,200°C.

The catalyst-free ceramic oven is the centrepiece of the QuickTOCpharma. At 1,200°C, it reliably dissolves all carbon bonds and thus enables a complete analysis of samples. Despite the high temperatures used, absolute safety is guaranteed in all settings. To this end, the QuickTOCpharma can be delivered with a number of different housings, depending on the intended location. That way the analyser itself can be safely at high corrosive places as well as in Ex-Zones.

Software. According to 21 CFR Chapter 11.

The software conforming to FDA (CFR 21 Chapter 11) permits inter alia data storage and an electronic signature in accordance with the requirements. The analysis system is fully controlled by the software and combines the high standards for the measurement of pharmaceutical waters, especially for HPW and WFI in one.

The QuickTOCpharma. Ultra quick measurements and maintenance.

The TRUE TOC measurement takes place in less than 3 minutes. The TRUE TC you even get in a minute. The TC is particularly advantageous if a high proportion of the TIC is present, which is hereby considered.

This speed guarantees that very short peaks can be determined very well during a daily cycle. The analyser's availability is over 98%. As even in high salt applications its weekly service is about 30 minutes.

Calibration and validation. Ready at any time.

LAR offers with the patented calibration and validation technique QuickCalibration the opportunity to check automatically and remotely at any time the analyser at any time. In contrast to the use of liquid standards, that must be produced or purchased expensively, our unique method uses a defined gas. Such a test gas is stable for a long time and is ideal for automatic calibrations without personnel on-site. So you can prove fast whether your analyser measures are correct.

The loop injection. For clean sample dosage.

The sample is injected into the furnace via an injection loop. Moreover, this loop defines simultaneously the sample volume. The loop system ensures that the sample is 100% closed against ambient air. Even the smallest impurities are excluded. The sample can be analyzed correctly in the lowest ppb range.

Contamination of test equipment in the loop system is technically impossible.