Effluent Monitoring Analyzer QuickTOCNPO

Up to 4 Parameters on ONE Analyser system - the cost effective monitoring of WWTP effluent

  • Total Organic Carbon (TOC),

  • Total Bounded Nitrogen (TNb),

  • Total Phophorus (TP) / Ortho-Posphate (o-P),

  • Chemical Oxygen Demand (COD) 

LAR's QuickTOCNPO is the ultimate online Analyser for the monitoring of WWTP effluent samples.  

Tracking pollution at 1,200°C.

The catalyst-free patented ceramic reactor is the centre piece of the QuickTOCNPO. At 1,200°C, all substances are oxidised without the use or catalysts which enables a complete analysis of samples. The QuickTOCNPO can be delivered with a number of different housings to suit even the most challenging environments with Ex-Zone I and II housings also available.   

The determination of TP / o-P with the use of molybdenum blue.

The Total Phosphorus / o-P is determined by the photometric molybdenum blue method. First the sample is mixed with an oxidising agent then the mixture is fed into the reactor where ultra violet light (UV) activates the sample‘s oxidation. Finally, by adding the molybdenum blue it becomes visible how much TP is in the sample.

Quick measurements and maintenance.

The TNb, TOC and COD measurements take place in less than 3 minutes with the sample being injected directly into the furnace. Maintenance and service requirements are minimal: Less than 30 minutes per week. The analyser‘s availability is over 98%.

Filtration free sample conditioning.

Normally the outlet or effluent of a WWTP is free of particles – or at least there are only a few. In this case the Analyser requires no additional hardware and can use the sample take-up directly from the sample line.  If however there is a high particulate density, the sample should be taken by the filterless, patented FlowSampler.  For more information on the Flowsampler click here

  • Measurement range: TOC: 0.1 - 200 mg/l, TNb: 0.1 - 200 mg/l, TP: 0.01 - 30 mg/l, COD: 1 - 600 mg/l
  • Response time: TOC / COD: 2 - 3 min, TNb: 1 - 3 min, TP: 10 - 15 min
  • Highest combustion temperature (1,200°C) available on the market
  • Photometric molybdenum-blue-method
  • Determination of all 4 parameters at the same time
  • Number of parameters are selectable
  • No filtration necessary
  • No memory effects
  • Very low maintenance and operational costs
  • According to DIN EN 1484:1997-08 (TOC), ISO 8245:1999-03 (TOC), EPA 415.1 (TOC), DIN EN 12260:2003 (TNb), ISO/TR 11905-2:1997 (TNb), DIN EN ISO 6878:2004-09 (TP), DIN EN ISO 15681-1:2005-05 (TP) and DIN EN ISO 15681-2:2005-05 (TP)
   QuickTOCNPO

Applications

Options

Housings

  • WWTP control
  • Process control
  • Surface water monitoring
  • Industrial and municipal WWTP
  • FlowSampler
  • Centrifugal separator
  • Single-parameter determination available
  • Combinations of 2 or 3 parameters obtainable

  • IP54 (Standard)
  • NEMA 4X
  • ATEX Zone I
  • ATEX Zone II

For additional information please contact us